Title: LOAD TEST ON SINGLE PHASE INDUCTION MOTOR
Page Link: LOAD TEST ON SINGLE PHASE INDUCTION MOTOR -
Posted By: fuzzu
Created at: Thursday 17th of August 2017 05:21:39 AM

AIM:
To determine the performance characteristics of the given single phase induction motor by direct loading.
APPARATUS REQUIRED:
Precaution

The motor should be started without any load.
Procedure
1. Note down the name plate details of motor. Connections are given as per the circuit diagram.
2. The DPST is closed in the supply side.
3. The motor is started by gradually varying the autotransformer and the rated voltage is applied.
4. At no load, the speed, current, voltage and power are noted down.
5 ....etc

[:=Read Full Message Here=:]
Title: LOAD TEST ON 3-PHASE SQUIRREL CAGE INDUCTION MOTOR
Page Link: LOAD TEST ON 3-PHASE SQUIRREL CAGE INDUCTION MOTOR -
Posted By: vasttrap
Created at: Thursday 17th of August 2017 05:14:21 AM

AIM:
To draw the performance characteristics of 3-phase squirrel cage induction motor by conducting load test.
THEORY:
A 3-phase induction motor consists of stator and rotor with the other associated parts. In the stator, a 3-phase winding is provided. The windings of the three phase are displaced in space by 120 .A 3-phase current is fed to the 3-phase winding. These windings produce a resultant magnetic flux and it rotates in space like a solid magnetic poles being rotated magnetically. ....etc

[:=Read Full Message Here=:]
Title: SEPARATION OF LOSSES IN THREE PHASE SQUIRREL CAGE INDUCTION MOTOR
Page Link: SEPARATION OF LOSSES IN THREE PHASE SQUIRREL CAGE INDUCTION MOTOR -
Posted By: bipul143
Created at: Thursday 05th of October 2017 04:35:14 AM

AIM:
To separate the no load losses of a 3 phase squirrel cage induction motor as iron losses and mechanical losses.
NAME PLATE DETAILS:
3 induction motor
Auto Transformer
FUSE RATING:
No load :10% of rated current (full load current).
PRECAUTIONS:
(1) The autotransformer should be kept in minimum voltage position.
(2) the motor should not be loaded throughout the experiment. ....etc

[:=Read Full Message Here=:]
Title: Load Test on Three Phase Induction Motor Squirrel gauge
Page Link: Load Test on Three Phase Induction Motor Squirrel gauge -
Posted By: ibinissac
Created at: Thursday 05th of October 2017 04:08:32 AM

Aim
To conduct load test on three-phase squirrel cage induction motor.
Apparatus Required
Precaution

The motor should be started without any load.
Procedure
1) Connections are given as per the circuit diagram.
2) The TPSTS is closed and the motor is started using star-delta starter to run at rated speed.
3) At no load the speed, current, voltage and power are noted down.
4) By applying the load gradually with the help of spring balance and brake drum arrangements.
5) The speed, current, volta ....etc

[:=Read Full Message Here=:]
Title: design optimization of three phase squirrel cage induction motor
Page Link: design optimization of three phase squirrel cage induction motor -
Posted By: vaibhav
Created at: Thursday 05th of October 2017 05:11:28 AM
there is a related thread for three phase squirrel cage induction motor , please go through the page link given below.

http://seminarsprojects.net/Thread-automatic-induction-motor-starter-with-programmable-timer ....etc

[:=Read Full Message Here=:]
Title: NO LOAD AND BLOCKED ROTOR TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR
Page Link: NO LOAD AND BLOCKED ROTOR TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR -
Posted By: vinu
Created at: Friday 06th of October 2017 03:13:38 PM

AIM:
To conduct the No Load test and Blocked rotor test on three phase squirrel cage induction motor and to draw the equivalent circuit.
FUSE RATING:
No load: 10% of rated current (Full load current)
Load: 125%of rated current (Full load current)
APPARATUS REQUIRED:
PRECAUTIONS:

The autotransformer should be kept at minimum voltage position.
PROCEDURE:
Note down the name plate details of motor.
1. For no-load open circuit test by adjusting autotransformer, apply rated voltage a ....etc

[:=Read Full Message Here=:]
Title: ACTIVE TWIST OF MODEL ROTAR BLADES WITH D-SPAR DESIGN
Page Link: ACTIVE TWIST OF MODEL ROTAR BLADES WITH D-SPAR DESIGN -
Posted By: baladari
Created at: Thursday 17th of August 2017 05:55:55 AM
ACTIVE TWIST OF MODEL ROTAR BLADES WITH D-SPAR DESIGN.


ABSTRACT


The design methodology based on the planning of experiments and response surface technique has been developed for an optimum placement of macro fiber composite (MFC) actuators in the helicopter rotor blades. The baseline helicopter rotor blade consist of D-spar made of UD GFRP, skin made of +45/-45 GFRP, foam core, MFC actuators placement on the skin and balance weight. 3D finite element model of the rotor blade has been built by ANSYS, where the blade skin ....etc

[:=Read Full Message Here=:]
Title: seperation of no load losses in three phase squirrel cage induction motor
Page Link: seperation of no load losses in three phase squirrel cage induction motor -
Posted By: vinu00
Created at: Thursday 05th of October 2017 03:49:47 AM
to get information about the topic seperation of no load losses in three phase squirrel cage induction motor full report refer the page link bellow

http://seminarsprojects.net/Thread-separation-of-losses-in-three-phase-squirrel-cage-induction-motor ....etc

[:=Read Full Message Here=:]
Title: brake test on three phase squirrel cage induction motor
Page Link: brake test on three phase squirrel cage induction motor -
Posted By: nazeem
Created at: Thursday 17th of August 2017 05:49:16 AM
brake test on three phase squirrel cage induction motor

The three phase induction motor is the most widely used electrical motor. Almost 80% of the mechanical power used by industries is provided by three phase induction motors because of its simple and rugged construction, low cost, good operating characteristics, absence of commutator and good speed regulation. In three phase induction motor the power is transferred from stator to rotor winding through induction. The Induction motor is also called a synchronous motor as it runs at a speed ....etc

[:=Read Full Message Here=:]
Title: NO LOAD AND BLOCKED ROTOR TEST ON 3- PHASE INDUCTION MOTOR
Page Link: NO LOAD AND BLOCKED ROTOR TEST ON 3- PHASE INDUCTION MOTOR -
Posted By: mallu4u
Created at: Friday 06th of October 2017 03:11:41 PM

AIM:
To conduct the no load & blocked rotor test on 3- phase induction motor
& to draw the equivalent circuit of 3- phase squirrel cage induction motor.
FUSE RATING :-
125/100 * 7.5 A 10A
THEORY :-
A 3-phase induction motor consists of stator, rotor & other associated parts. In the stator
,a 3- phase winding (provided) are displaced in space by 120. A3- phase current is fed to the winding so that a resultant rotating magnetic flux is generated. The rotor starts rotating due to the induc ....etc